Navigating the specifics of fire door compliance can be technical and time-consuming. As part of a comprehensive fire safety strategy, regular professional assessments are vital. At HawkSwift, our NEBOSH-qualified assessors can evaluate your premises, identify fire door defects, and help you meet your obligations under the RRO.
We provide detailed fire risk assessments starting from £199 + VAT, with reports delivered within 48 hours. To ensure your fire safety measures are up to standard, contact us today to book a fire risk assessment.
<!-- expanded-by-hawkswift-bot -->
Your duties under the RRO 2005 on fire doors
- Article 17 requires fire doors to be maintained in efficient working order.
- A door that does not self-close fails the duty; propping open is an offence unless via an approved hold-open device linked to the alarm.
- Intumescent seals and certified installation matter at inspection.
Frequently asked questions
Do I need a written fire risk assessment? Yes, if you employ 5+ people, are a licensable or higher-risk premises, or the building is not a private home (Art. 9). How often should I review it? At least annually and immediately after any significant change. Can I do my own? Only if you are competent; many use a qualified NEBOSH-assessed assessor for a court-defensible report. Where do I start? Book a HawkSwift assessment — general guidance, not formal legal advice.
*General guidance, not formal legal advice — book a HawkSwift assessment for your premises.*
<!-- pas79-block -->
What a competent fire risk assessment covers
A suitable and sufficient FRA follows the PAS 79-1 methodology:
- Stage 1 — Preliminary: gather premises info, identify responsible person and previous assessments.
- Stage 2 — Identify hazards: sources of ignition, fuel and oxygen across all areas.
- Stage 3 — People at risk: occupants, visitors, contractors and anyone needing assistance.
- Stage 4 — Evaluate & protect: whether risks are eliminated or reduced, and whether fire precautions are adequate.
- Stage 5 — Record & plan: write it down, set an action plan with owners and dates, and set the review date.
HawkSwift delivers this as a written, court-defensible report — general guidance, not formal legal advice.